| Application | Integrates control of all combustion blower and circulating fan operations for a gas warm air appliance. |
|---|---|
| Approvals and Standards | UL Listed: Report MP466|CSA Certified: File No. LR95329-17 |
| Heat Fan Off Delay Timing | Adjustable 90, 120, 150, 180 sec (set at 120 sec) |
| Heat Fan On Delay Timing | Fixed, 20 sec |
| Cool Fan Off Delay Timing | Fixed 0 sec |
| Cool Fan On Delay Timing | Fixed 0 sec |
| Current Draw | 4 VA at 24 V AC |
| Electrical Ratings | 24 Vac |
| Power Supply Frequency | 50 Hz|60 Hz |
| Operating Voltage | 24 Vac |
| Ambient Operating Temperature (Max) | 160 °F|70 °C |
| Ambient Operating Temperature (Min) | -40 °F|-40 °C |
- Central appliance wiring point simplifies appliance assembly and service.
- Fixed or field-adjustable heat fan on delay; field adjustable heat fan off delay.
Accessories (0)
| Image | SKU | Name | |
|---|---|---|---|
| No items found. |
Replacement Parts (0)
| Image | SKU | Name | |
|---|---|---|---|
| No items found. |
Direct Replacement (0)
| Image | SKU | Name | |
|---|---|---|---|
| No items found. |
Functional Replacement (0)
| Image | SKU | Name | |
|---|---|---|---|
| No items found. |
Universal Replacement (1)
| Image | SKU | Name | |
|---|---|---|---|
![]() |
s-st9120u1011-u | Universal Electronic Fan Timer | Sign In to View Pricing |