Resources Specifications Overview Parts & accessories Replacement products
Technical (0)
| Title | Date Posted | Size | ||
|---|---|---|---|---|
| No results found for "brochure". |
Sales (0)
| Title | Date Posted | Size | ||
|---|---|---|---|---|
| No results found for "brochure". |
Submittal (0)
| Title | Date Posted | Size | ||
|---|---|---|---|---|
| No results found for "brochure". |
Training (0)
| Title | Date Posted | Size | ||
|---|---|---|---|---|
| No results found for "brochure". |
| Application | Water Heater Control |
|---|---|
| Approvals and Standards | CSA Certified: ANSI Z21.20, ANSI Z21.23, ANSI Z21.35, ANSI Z21.78, ANSI Z21.87, ANSI Z21.94 (report 158158-1701693) |
| Capacity (Min) | 30 Btuh |
| Capacity (Max) | 75 Btuh |
| Ignition Type | Hot Surface Ignition |
| Type of Fuel | LPG |
| Sensor Type | NTC thermistor |
| Body Pattern | 90 degree |
| Inlet Pressure (Max) | 10.0 in w.c. |
| Control Input Voltage (Min) | 98 Vac at 60 Hz |
| Control Input Voltage (Max) | 132 Vac at 60 Hz |
| Mounting Type | Mount in the upright position |
| Inlet Connection Size | 1/2 in |
| Inlet Connection Type | NPT |
| Outlet Connection Size | 1/2 in |
| Outlet Connection Type | Inverted Flare |
| Set point Temperature (Min) | 32 °F|0 °C |
| Set point Temperature (Max) | 150 °F|65 °C |
| TCO Cutout Temperature | 189 °F|87 °C |
| Shipping and Storage Temperature (Min) | -20 °F|-29 °C |
| Ambient Operating Temperature (Max) | 150 °F|66 °C |
| Ambient Operating Temperature (Min) | 32 °F|0 °C |
| Shipping and Storage Temperature (Max) | 120 °F|49 °C |
| Operating Relative Humidity (Max) | 95% Non-condensing at 104 °F|95% Non-condensing at 40 °C |
- Gas regulation
- Hot surface ignition
- Flame supervision using flame rectification sensing through the igniter. This flame sense circuit uses patented technology to create a robust sensing signal that is independent of AC line polarity and appliance earth grounding
- Water temperature sensing using NTC sensors potted in a submersion well assembly
- Manually resettable High Temperature Cutout (TCO)
- Induced draft blower motor control
- Draft proving via pressure switch
- Retains up to 10 fault code histories in non-volatile memory (available through the EnviraCOM™ communication port)
- Solid state setpoint adjustment over a factory preset temperature range using a linear potentiometer to provide high resolution adjustment
Accessories (0)
| Image | SKU | Name | |
|---|---|---|---|